Stuurkaart, digitale ingangen:
Aantal programmeerbare digitale ingangen .......................................................................................................... 8
Klemnummers ........................................................................................................ 16, 17, 18, 19, 27, 29, 32, 33
Spanningsniveau .............................................................................................. 0 -24 V DC (PNP positieve logica)
Spanningsniveau, logische '0' .................................................................................................................. < 5 V DC
Spanningsniveau, logische '1' ................................................................................................................. >10 V DC
Maximumspanning bij ingang ................................................................................................................... 28 V DC
Ingangsweerstand, R
.................................................................................................................................... 2 k
i
Scantijd per ingang ........................................................................................................................................ 3 ms
Betrouwbare galvanische isolatie: Alle digitale ingangen zijn galvanisch geïsoleerd van de netvoeding
(PELV), met uitzondering van VLT 5001-5250, 550-600 V. Daarnaast kunnen de digitale ingangen worden
geïsoleerd van de andere klemmen op de stuurkaart door aansluiting van een externe voeding van 24 V
DC en openen van schakelaar 4. Zie de sectie over de installatie van stuurkabels.
Stuurkaart, analoge ingangen:
Aantal programmeerbare analoge spanningsingangen/thermistoringangen .......................................................... 2
Klemnummers ............................................................................................................................................. 53, 54
Spanningsniveau .......................................................................................................... 0 - ±10 V DC (schaalbaar)
Ingangsweerstand, R
.................................................................................................................................. 10 k
i
Aantal programmeerbare analoge stroomingangen ............................................................................................
Klemnummer ...................................................................................................................................................... 60
Stroombereik ................................................................................................................ 0/4 - ±20 mA (schaalbaar)
Ingangsweerstand, R
.................................................................................................................................. 200
i
Resolutie .......................................................................................................................................... 10 bit + teken
Nauwkeurigheid aan ingang ............................................................................. Max. fout 1% van volledige schaal
Scantijd per ingang ........................................................................................................................................ 3 ms
Klemnummer aarde ............................................................................................................................................ 55
Betrouwbare galvanische isolatie: Alle analoge ingangen zijn galvanisch geïsoleerd van de netspanning
(PELV), met uitzondering van VLT 5001-5250, 550-600 V, en andere ingangen en uitgangen.
Stuurkaart, puls-/codeeringang:
Aantal programmeerbare puls-/codeeringangen ................................................................................................... 4
Klemnummers ................................................................................................................................. 17, 29, 32, 33
Max. frequentie op klem 17 ......................................................................................................................... 5 kHz
Max. frequentie op klem 29, 32, 33 .......................................................................... 20 kHz (PNP open collector)
Max. frequentie op klem 29, 32, 33 .......................................................................................... 65 kHz (Push-pull)
Spanningsniveau .............................................................................................. 0 -24 V DC (PNP positieve logica)
Spanningsniveau, logische '0' .................................................................................................................. < 5 V DC
Spanningsniveau, logische '1' ................................................................................................................. >10 V DC
Maximumspanning bij ingang ................................................................................................................... 28 V DC
Ingangsweerstand, R
.................................................................................................................................... 2 k
i
Scantijd per ingang ........................................................................................................................................ 3 ms
Resolutie .......................................................................................................................................... 10 bit + teken
Nauwkeurigheid (100 Hz-1 kHz), klem 17, 29, 33 ....................................... Max. fout: 0,5% van volledige schaal
Nauwkeurigheid (1-5 kHz), klem 17 ............................................................. Max. fout: 0,1% van volledige schaal
Nauwkeurigheid (1-65 kHz), klem 29, 33 .................................................... Max. fout: 0,1% van volledige schaal
Betrouwbare galvanische isolatie: Alle puls-/codeeringangen zijn galvanisch geïsoleerd van de netvoeding
(PELV), met uitzondering van VLT 5001-5250, 550-600 V. Daarnaast kunnen puls- en codeeringangen
worden geïsoleerd van de andere klemmen op de stuurkaart door aansluiting van een externe voeding
van 24 V DC en openen van schakelaar 4. Zie de sectie over stuurkabels.
12
®
VLT
Serie 5000
MG.51.A3.10 - VLT is een geregistreerd handelsmerk van Danfoss
1