23. Filling pump
The filling pump is used for pumping the water from the external tank to the JMB-M water tank.
There is a float protection in the water tank thus to prevent that the filling pump continues to pump water (over-
flow protection) from the external tank to the JMB-M water tank. The filling pump can run dry without any damage.
It will, however, reduce unnecessary battery power. The filling pump can be switched on/off through the display.
See also added manual of the filling pump. The filling pump can work approx. 15 minutes after the engine has
been stopped. Use the pump only with clear water! The overflow protection of the water tank ensures that the
pump will stop automatically when the tank is filled with water.
24. 'Greenkiller' valve
The 'greenkiller' function is a function that allows to prevent growth of weeds and/or moss growth using a hot
water principle. This valve is located below the control panel against the frame.
Valve horizontal: 'greenkiller' function activated (see symbol underneath - use the appropriate lance).
Valve vertical: pressure washing activated (see symbol underneath - use the appropriate lance).
High pressure mode
High temperature mode
JMB-M greenkiller: REV B
DiBO n.v. 92