5.1.2

Installation example bituminous membrane (floor slab with separating layer)

1 Pumpfix F
2 Seal set art. no. 83073: extension
section with flange and counter-
flange (for connection to an on-site
sealing sheet)
3 Extension section art. no. 83070
a Floor covering
f Protective con-
crete
b Screed
g Control unit
c Insulation
h Cable conduit
d Concrete floor
BWS* design
water level
e Waterproofing
layer
5.2
Mount and align the drain body
Connect the two sockets on the inlet (3) and outlet side
(1) to the drain body (2).
The quick-release closures (4) on the drain body enable
fast installation.
Connect the backwater pumping station to the pipe sys-
tem.
(A)
Floor slab installation
(B)
Installation in exposed drainage pipe
(C)
Arrow for flow direction
Always pay attention to the direction of flow (see arrow
(C)).