V11, V12
PURGE SHUT OFF VALVES ON COLLECTING PIPE
Through the purge valves it is possible to ventilate the high pressure collecting pipes on the
empty side before removing high pressure hoses from the cylinders. The purge valve are also
used for cleaning the collecting pipes before opening the inlet shut off valves and supplying
gas to the manifold.
V13, V14
INLET SHUT OFF VALVES ON COLLECTING PIPES
If collecting pipes are used, inlet shut off valves and non-return valves shall be included. Shut
off valves stops the gas supply between each cylinder and the collecting pipes.
H1, H2
CYLINDERS HOLDERS
The accessories can contain cylinders holders. Cylinder holders are used for prevention of the
EN
gas cylinders from falling over.
6. INSTALLATION
It is necessary that an installer of the product is trained and has an appropriate licence ac-
cording to national standards. It is outside the scope of these operating instructions to give
detailed guidance on installations.
The installation must conform to the standard MEDICAL GAS PIPELINE SYSTEMS EN ISO
7396-1 as amended. All tests according this standard have to be fulfi lled.
When working with medical gases it is essential that no oil or grease come into contact with
the gas. This means that hands, tools and work clothes be free from oil or grease before any
work is undertaken. Components used for service must be gas compatible. For oxygen ser-
vice must also be degreased and although they will reach you in this condition care must be
taken during storage and handling.
6.1. WALL FIXING
Positioning of the manifold, please consult with responsible central gas system designer. Mount
the manifold at the height to suit either cylinders or cylinder bundles.
The holes to use for mounting the manifold are shown in Fig. 3.
Be aware that only upper screw is holding the entire weight of the manifold. Size of used
screws shall conform to total load.
Fig. 3