ANNEX A: FREQUENT TERMS
Numerical code stored in both the transmitter and receiver unit. The receiver unit
Configuration ID
can only be controlled by a transmitter with the correct configuration ID.
Continuous radio
When in continuous radio mode the transmitter unit transmits continuously when
mode
it is switched on.
Numerical code stored in the transmitter unit, used to replace the unique ID code.
Custom ID
One or several transmitter units can be configured with the same custom ID and
the receiver will recognise them all as the same transmitter unit.
When in discontinuous radio mode the transmitter unit transmits whenever it is
Discontinuous radio
switched on and a button is pressed. The transmission is interrupted when all but-
mode
tons are released.
Function relay
Standard relay, controlled by the buttons on the transmitter unit.
Prevents a component from functioning when another component is functioning
Interlocking
or operating in a particular way.
Latching relay
The relay becomes active every time you press a button and remains active until
functionality
the button is pressed again.
One or more Load select modes are stored in the transmitter unit. Activating a spe-
Load select mode
cific Load select mode results in a group of preselected relays on the receiver unit,
which may be controlled from the transmitter unit.
Momentary relay
The relay will only be active while a button is pressed on the transmitter. When
functionality
the button is released, the relay will no longer be active.
Relay that is active when the receiver unit is operating and a radio link is estab-
On relay
lished, regardless of whether any other relays are active.
One or more Operating modes are stored in the receiver unit. Each Operating
Operating mode
mode describes which relays on the receiver unit are controlled when specific but-
tons on the transmitter unit are pressed.
Replace ID
Numerical code used to identify the transmitter during the Replace procedure.
Safety related relay controlled by the stop button on the receiver. Intended to inter-
Stop relay
rupt the power supply to a safety application controlled by the receiver unit.
Relay that is active when any other specified relay(s) on the receiver unit is/are act-
Work relay
ive.
Security function ensuring that potentially active buttons/joysticks upon start up
Zero position check
or lost/found radio links must be in the zero position before the system can be
used to avoid unplanned movements of the controlled object.
- 27 -