GB
1. GENERAL SAFETY
INFORMATION
Please read through these operating
instructions carefully and make yourself
conversant with the control elements and
the proper use of this product. We shall
not be liable in the case of damage caused
as a result of the non-observance of
instructions and provisions of the present
operating instructions. Any damage caused
as a result of the non-observance of the
instructions and regulations contained in
the present operating instructions shall not
be covered by the warranty terms. Please
keep these operating instructions in a safe
place and hand them on together with the
device should you ever dispose of it.
• Persons not conversant with the contents
of these operating instructions must
not use this device. This appliance can
be used by children aged from 8 years
and above and persons with reduced
physical, sensory or mental capabilities
or lack of experience and knowledge
if they have been given supervision
or instruction concerning use of the
appliance in a safe way and understand
the hazards involved. Children shall not
play with the appliance. Cleaning and
user maintenance shall not be made by
children without supervision.
• The pump must not be used when people
are in the water.
• The pump must be supplied through a
residual current device (RCD) having
a rated residual operating current not
exceeding 30mA.
• If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in
order to avoid a hazard.
• Disconnect the device from the power
supply and let it cool down before
cleaning and maintenance is performed
and before the device is stored.
• Always protect electrical parts against
moisture. During cleaning or operation,
they must not be immersed in water or
other liquids to ensure that an electrical
shock is prevented. Never hold the
device under running.
• Notes and instructions with the following symbols
require particular attention :
Any non-observance of these instructions
involves the danger of bodily harm to
people and/or damage to property.
Any non-observance of this instruction
bears the risk of an electrical shock which
may cause damage to persons or property.
Please inspect the device for damage occurred
during transportation. In case of damage, the
retailer has to be informed immediately, at the
latest within 8 days after the date of purchase.
2. RANGE OF USE
Garden pumps from SPIDO are highly efficient self-
priming electrical pumps for discharging clear, clean
or moderately dirty water containing solids up to
the maximum size specified in the technical details.
These high-quality products with their convincing
performance data were developed for the multiple
purposes involved with irrigation, draining, water
withdrawal as well as for the further conveyance of
water under pressure.
The typical ranges of application of garden pumps
include : filling or emptying of storage containers,
basins and ponds, water withdrawal from wells or
cisterns, flushing down of terraces and boardwalks.
The device is not suited for use in swimming pools.
This product was developed for private use, i.e.
non-for industrial applications or for continuous
operation.
The pump is not suited to discharge
saltwater, faeces, inflammable, etching,
explosive or other hazardous liquids.
Please observe the max. and min.
temperatures of the liquids to be discharged stated
in the technical data.
3. TECHNICAL DATA
Model
JETCOM 550-KIT 7 m
Mains voltage / Frequency
230/50
(V / Hz)
Nominal performance (Watts)
550
Protection type (IP)
x4
Suction port
M26/34 (1")
Pressure port
M26/34 (1")
Max. flow rate (Qmax)
(l/h)
2 800
(1)
Max. pressure (bar)
4,2
Max. delivery height
42
(Hmax)
(m)
(1)
Max. suction height (m)
7
Max. size of the solids being
3
pumped (mm)
Min. ambient temperature (°C)
5
Max. ambient temperature (°C)
35
Min. fluid temperature (°C)
5
Max. fluid temperature
35
(Tmax) (°C)
Length of connection cable (m)
1,5
Cable type
H07RN-F
Weight (net) (kg)
5,6
Guaranteed sound power level
80
(LWA)
(dB)
(2)
Measured sound power level
78,2
(LWA)
(dB)
(2)
Dimensions (L x D x H) (mm)
360 x 174 x 246
1) The values were determined with free, unreduced in- an
outlet.
2) Noise emission values obtained according to the EN 12639
regulation. Measurement method according to EN ISO
3744.
4. SCOPE OF DELIVERY
The scope of the delivery of this product includes :
One pump with connection cable + suction hose +
garden hose.
Please verify that the scope of delivery is complete.
Depending on the purpose of the application,
additional accessories may be necessary (please
refer to the chapters titled "Installation", "Automation
with special accessories").
If possible, keep the packing until the warranty
period has expired. Please dispose of the packing
materials in an environmental-friendly manner.
5. INSTALLATION
5.1. GENERAL INSTALLATION INFORMATION
During the entire process of installation, the
device must not be connected to the
electrical mains.
The pump should be installed in a dry place
with an ambient temperature not to exceed
40 °C and not to fall below 5 °C. The pump
and the entire connection system have to be
protected from frost and other climatic influences.
When installing the device, please make
sure that the motor is sufficiently ventilated.
All connection lines have to be perfectly tight since
leaking lines may affect the performance of the
pump and cause considerable damage. Therefore,
please use Teflon tape to seal the contact surfaces
between the threaded sections of the lines and
the connection with the pump. This use of sealing
material such as Teflon tape is the only way to ensure
an airtight assembly.
When tightening threaded connections, please
do not apply excessive force which may cause
damage. When laying the connection pipes, you
should make sure that the pump is not exposed to
any form of weight, vibration or tension. Moreover,
the connection lines must not contain any kinks or
an adverse slope.
5.2. INSTALLATION OF THE SUCTION LINE
The intake of the suction line (1) has to be
equipped with a check valve (or non-return
valve) and an intake filter.
Please use a suction line having the same diameter as
the suction port (4) of the pump. If the suction height
(HA) exceeds 4 m, however, it is recommendable to
use a 25% larger diameter - including appropriate
reducer elements for the connectors.
The intake of the suction line has to be equipped
with a check valve (8) - or non-return valve - and an
intake filter (3). The filter will keep away larger dirt
particles contained in the water which might clog or
even damage the piping. The check valve will prevent
the pressure to escape after the pump has cut out.
Moreover, it simplifies the venting of the suction line
by enabling water to be filled in. The check valve
with the intake filter - i.e. the entirety of the intake
section of the suction port - must be immersed by
at least 0.3 m below the surface of the liquid to be
pumped (HI). This will prevent air from being taken in.
In addition, please ensure a sufficient distance of the
suction line from both the ground and the sides of
water courses, rivers, ponds etc in order to prevent
stones, plants etc from being sucked in.
GB