Connection value:
RCD:
Input under voltage protection:
Input overvoltage protection:
Input Power Derating:
DC OUTPUT
Output power:
Constant power range:
Output voltage range:
Output current range:
Output overvoltage protection:
Output under voltage alarm:
Voltage stabilized accuracy:
Max. startup overshoot:
Current stabilized accuracy:
Startup Time:
Efficiency:
OPERATING ENVIRONMENT
Operating temperature:
Overtemperature protection:
Operating/ambient temperature:
Storage temperature:
Humidity:
Pressure/Altitude:
3 x 180A
(With a lower available capacity, the
charger can be set lower by soft-
ware)
Type B
255V ±5V
535V ±5V
260V ±5V<Vin<304V±5V,
Linear power derating from 100% to
50%
1 - 120 kW @CCS or 1 - 60 kW @
CHAdeMO
CCS 120KW @ 400-500V CHAdeMO
60KW @ 400-500V (300 -1000vdc on
request)
150 ~ 500V (200-1000vdc on request)
CCS: 0~250A (500A peak) ,
CHAdeMO: 0~130A
510±5V
140V±2V
≤±0.5%
≤±1%
≤±1%
Normally 3s ≤ t ≤ 8s
>96%
-30°C ~ 70°C, derating from 55°C
On temperature >70°C±4°C or
<-40°C±4°C, charger will shut down
automatically
-25°- to 60°
- 40°C ~ 85°C
≤ 95% RH, without condensation
79kPa~106kPa/2000m
25