RMD10
WARNING type fault messages
All faults of the WARNING type are reset automatically once the fault has been
rectified.
RMD10.5,
RMD10.5T,
RMD10.5X,
RMD10.5XT
RMD10.5S,
RMD10.5XS:
W01
W05
W06
W11
W10
+ beep
ERROR type fault messages
All faults of the ERROR type must be reset manually:
➤ RMD10.5T, RMD10.5XT: Press the control knob for 2 seconds.
➤ RMD10.5, RMD10.5X, RMD10.5S, RMD10.5XS: Press
✓ A beep sounds.
✓ The error has been reset.
EN
Fault
Defective temperature
sensor in the refrigerator
compartment
AC power not connected or
AC voltage < 190 V
DC power not connected
DC overvoltage (> 16 V)
Tank stop mode: Gas opera-
tion is blocked for
15 minutes.
Beep
The door is opened for more
than 2 minutes.
Troubleshooting
Solution
Contact an authorized customer
service.
Connect the refrigerator to AC or
select a different energy type, e.g.
gas or DC.
Connect the refrigerator to DC or
select a different energy type, e.g.
gas or AC.
Reduce the DC supply voltage.
Wait 15 minutes or switch to another
operating mode.
Close the door.
for 2 seconds.