Connecting the refrigerator-oven combination
It must be possible to shut off the refrigerator-oven combination from the gas line
separately by means of a shut-off device. The shut-off device must be easily
accessible.
➤ Connect the refrigerator securely by hand to the gas supply (fig. l, page 12):
Please note the following information:
Item in
fig. l,
Description
page 12
1
Screw M4 (Torx TX20),
Tightening torque: 2 Nm
2
Refrigerator gas connection:
M14 x 1.5 (d = 8 mm/ISO8434 (DIN2353))
3
Gas pipe with ring coupling (size 17),
Tightening torque: 25 Nm
➤ Have a leak test and a flame test performed by an authorized specialist after
professional installation.
Ensure you are issued with a certificate of inspection.
5.2

Connecting to DC and AC

A
NOTICE!
The electrical installation and repairs may only be performed by a spe-
cialist in accordance with the applicable regulations and standards.
I
NOTE
• The device plug must not be placed directly behind the ventilation
grill in order to prevent the air circulation from being impaired and to
protect the device plug from splashes of water.
• The device plug of the AC connection cable must not be cut off.
• The connection cables must be laid so that they do not come in con-
tact with hot parts of the unit/burner or with sharp edges.
• Changes to the internal electrical installation or the connection of
other electrical components (e.g. extra third party fans) to the inter-
nal wiring of the refrigerator will void any claims from the guarantee
and product liability.
• The refrigerator has a CI bus interface and can be controlled through
a compatible central vehicle display.