• If the minimum distance between the air inlet and outlet vents cannot be met, a
roof vent must be installed instead of the air outlet vent.
– The roof vent should be installed directly above the back of the refrigerator as
far as this is possible. Use an air duct (fig. 6 1, page 6) if you need to install
the roof vent offset; otherwise, heat will accumulate there.
– Fit a nonflammable heat conduction plate (fig. 6 2, page 6) above the
refrigerator so that the refrigerator does not heat up the oven.
– The distance between the air inlet vent and the roof vent must be at least
1800 mm (fig. 6, page 6).
– If a roof air conditioner is provided, the distance between the roof vent
(fig. 7 1, page 6) and the air outlet of the roof air conditioner (fig. 7 2,
page 6) must be at least 300 mm.
• The distance between the top of the oven and the ceiling must be at least 55 mm
(fig. 2, page 4).
• The distance in front of the oven between the top of the oven to the ceiling must
be at least 90 mm (fig. 3, page 4).
• The distance between the top of the oven and the flue outlet of the roof flue must
be between 250 mm and 1500 mm (fig. 4, page 5).
• If a roof flue (fig. 2 4, page 4) is being used: Fit a detachable panel (fig. 2 5,
page 4) above the oven so that you can always reach the flue pipe.
• If you do not have a roof flue: Fit a panel with a ventilation grille (fig. 8 1, page 7)
above the oven.
• The refrigerator-oven combination must not be installed at the side of the air inlet
and outlet vents as this leads to poor performance and increases the power con-
sumption of the refrigerator.
• The air inlet and outlet vents must not be covered by vehicle parts (such as an
open door or by installing accessories such as bicycle racks) while operating.
• Install the refrigerator-oven combination so that it is protected from excessive
heat, as this leads to poor performance and increases the power consumption of
the refrigerator.
• The refrigerator-oven combination must be installed in a draft-proof location, see
chapter "Installing the refrigerator-oven combination in a draft-proof location" on
page 20.
• The electrical installation must comply with national and local regulations.
European standards: EN 60335-1, EN 60335-2-24, EN 1648-1 and EN 1648-2.
• The gas installation must comply with national and local regulations.
European standard: EN 1949.