Put on the door panel
8
Put on the door panel
A
NOTICE! Beware of damage
Only ever lay the refrigerator on its side and never on its back. Otherwise
the unit may be damaged.
The door panel must have the following dimensions:
• 740 x 455 x max. 3 – 3.8 (H x W x D in mm)
➤ Put on the door panel as shown (fig. c, page 9).
9
Connecting the refrigerator
9.1
Connecting to the gas supply
A
NOTICE!
• This refrigerator may only be connected to the gas supply by a
specialist in accordance with the applicable guidelines and
standards.
• Only use cylinders of propane or butane gas (not natural gas or city
gas) with an approved pressure reduction valve and suitable head.
Compare the pressure information on the type plate with the pres-
sure information on the pressure regulator on the propane or butane
gas cylinder.
• Only operate the refrigerator at the pressure shown on the type
plate.
• Please note the pressures which are permitted in your country. Use a
DIN-DVGW-approved pressure regulator with a fixed setting:
– The following applies for Germany: DIN EN 12864
– The following applies for Europe: EN 732 and EN 1949
I
NOTE
The refrigerator is equipped for a connection pressure of 30 mbar. Use
a Truma VDR 50/30 back-pressure regulator when connected to a
50 mbar system.
It must be possible to shut off the refrigerator from the gas line separately by means
of a shut-off device. The shut-off device must be easily accessible.
20
RMV5301, RMV5305
EN