Mounting and Installation
2.20
(56)
4.52
(115)
3.2
(81)
CO
Exhaust
1
CAUTION: Fasten pump securely to rack or
mounting board. Refer to Figure 4 for minimum and
maximum operating parameters. Refer to Figure 2 for
maximum height requirement and Figure 5 for a typical
initial installation.
Operation
CAUTION: Do not exceed 90 PSI (6.2 BAR) total gas
inlet pressure and liquid inlet pressure. - See Fig 4.
Inlet pressure in excess of 30 PSI requires the installa-
tion of a water pressure regulator (Flojet's 01752XXX or
01754XXX Series Water Pressure Regulator) on the fluid
inlet line, before the pump, limiting water inlet pressure
to 30 PSI (2.1 BAR). - See Fig 5.
Hose Connections
CAUTION: For product hose use food grade vinyl
hose or equivalent.
CAUTION: It is advisable to secure all hoses to
prevent excessive movement.
WARNING: Pump is NON-REPAIRABLE. Do not
modify or alter the pump in any way as this could
lead to CO
or liquid leaks resulting in property
2
damage, severe personal injury and/or death.
DANGER
ASPHYXIATION HAZARD
If used with CO
well ventilated or gas is exhausted to outside atmosphere
WARNING
EXPLOSION HAZARD
Only used with specified products. DO NOT
PUMP LIQUIDS WITH A FLASH POINT BELOW 100°F (37.8°C)
OR USE WHERE FLAMMABLE VAPORS ARE PRESENT.
4.58
(116)
Liquid
Out
2
.74
(17)
CO
2
Liquid
Inlet
In
or N
be sure the area is
2
2
via hose.
2
10 FEET
(3.05 m)
5.27
(134)
MAX
.92
(23)
1.84
(47)
3
20 PSI (1.4 BAR)
Minimum
CO
2
or
N
2
CO
Supply
2
65 PSI (4.5 BAR)
01752XXX or 01754XXX
Water Pressure Regulator
5
2
Pump Symbols
Liquid In
Oetiker
Clamp
90
15
OR
15 PSI (1.0 BAR)
Minimum
90 PSI (6.2 BAR)
Maximum
G60 Series
Pumps
30 PSI (2.1 BAR) MAX
Liquid Out
4
120°F (49°C)
Safe Fluid
Operating
Temperature
34°F (1.1°C)