Download Inhoudsopgave Inhoud Print deze pagina

Wiring Diagram; Heat-Up Diagrams; Fault Conditions; Details On Energy Consumption - Stiebel Eltron PSH 30 Trend Handleiding Voor Bediening En Installatie

Inhoudsopgave

Advertenties

INSTALLATION
Specification
Wall mounting bracket
30 - 50 l
80 - 200 l

15.2 Wiring diagram

1
2
L
N
1 Terminal
2 High limit safety cut-out
3 Temperature controller
4 ON/OFF indicator
5 Heating element
6 Electrical resistance 560 ohm
7 Anode
8 Cylinder

15.5 Details on energy consumption

Product datasheet: Conventional water heaters to regulation (EU) no. 812/2013 and 814/2013 / (S.I. 2019 No. 539 / Schedule 2)
Manufacturer
Load profile
Energy efficiency class
Energy conversion efficiency
%
Annual power consumption
kWh
Default temperature setting
°C
Sound power level
dB(A)
Daily power consumption
kWh
www.stiebel-eltron.com
184
265
300
360
265
300
350
360
415
450
3
4
5
8
7
6
PSH 30 Trend PSH 50 Trend PSH 80 Trend PSH 100 Trend PSH 120 Trend PSH 150 Trend PSH 200 Trend
232080
232081
STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON
S
M
C
C
34
37
544
1386
60
60
15
15
2591
6451

15.3 Heat-up diagrams

The heat-up time depends on the cylinder capacity, cold water
inlet temperature and heating output.
Graph assumes 15 °C cold water inlet temperature:
6
5
4
3
2
1
0
35
45
X Temperature setting [°C]
Y Heat-up time [h]
1 200 l
2 150 l
3 120 l
4 100 l
5 80 l
6 50 l
7 30 l

15.4 Fault conditions

In the event of a fault, temperatures of up to 95 °C at 0.6 MPa
can occur.
232082
232083
M
L
C
C
36
38
1412
2716
60
60
15
15
6603
12583
1
2
3
4
5
6
7
55
65
75
232084
232085
L
L
C
C
38
37
2723
2763
60
60
15
15
12622
12861
PSH Trend |
232086
XL
C
38
4367
60
15
20133
23

Advertenties