Warning: In order to prevent tipping of the
appliance, this stabilizing means must be
installed. Refer to the instructions for in-
stallation.
If your product has 2 safety chains;
Fasten hook (1) by using a proper peg to
the kitchen wall (6) and connect safety
chain (3) to the hook via the locking mech-
anism (2).
1
Hook
2
Locking mechanism
3
Safety chain
4
Firmly fix chain to product rear
5
Rear of product
6
Kitchen wall
If your product has 1 safety chains;
The appliance must be secured against
overbalancing by using the supplied one
safety chain on your oven.
Follow below steps in the picture to secure
the safety chain to your product.
Stability chain to be as short as
practicable to avoid oven tilting for-
ward and diagonal to avoid oven
side tilting. Stability chain is de-
signed for cookers without a
bracket engagement slot.
Room ventilation
All rooms require an openable window, or
equivalent, and some rooms will require a
permanent vent as well. The air for com-
bustion is taken from the room air and the
exhaust gases are emitted directly into the
room. Good ventilation is essential for safe
operation of your appliance.
Rooms with doors and/or windows which
open directly to the outer environment
The doors and/or windows that open dir-
ectly to the outer environment must have a
total ventilation opening of the dimensions
specified in the table below which is based
on the total gas power of the appliance
(total gas power consumption of the appli-
ance is shown in the technical specification
table of this user manual). If the doors and/
or windows do not have a total ventilation
opening corresponding to the total gas con-
sumption of the appliance as specified in
the table below, then there must definitely
be an additional fixed ventilation opening in
the room to ensure that the total minimum
ventilation requirements for the total gas
consumption of the appliance is achieved.
EN / 24
EN
NL