Advertenties

• Check that the electrical socket is in
good condition and that it is sufficiently
fused (at least 10 A).
• Make sure that moisture or water can
never get into the mains connection.
Otherwise, there is a risk of electric
shock.
• Putting back into operation after
storage: The pressure accumulator
(7) must show an air pressure of 0.15
MPa (1.5 bar) in an unused condition.
Check the air pressure before putting
back into operation.
The air pressure can only be checked
with an external pressure gauge, e.g.
with a tyre filler or manometer. The
mounted pressure gauge (11) only
shows the water pressure.
Regulate the pressure in the pressure
accumulator (7) by removing the pro-
tective cap for the air valve (16) and
pumping air into the pressure accumu-
lator via the air valve (17) or allowing
air to vent.

Starting the device

Connect the mains connection cable
(9) to the power supply.
Turn the device on using the on/off
switch (15).
If water is demanded, the automatic
switch (12) will activate automatically
if the pressure falls in the pressure ac-
cumulator (7) and the pump will switch
on. Once the water stops flowing the
vessel pressure will increase and the
automatic switch will switch the pump
off.

Cleaning and storage

Clean and maintain the filter (2) regularly.
This will ensure good performance and a
long service life.
Have any work that is not described
in this instruction manual performed
by our service centre. Only use ori-
ginal parts.
Always remove the mains plug be-
fore working on the device.
There is a risk of electric shock or
injury from moving parts.

Cleaning the filter

Make sure that the filter (2) is cle-
aned regularly to maintain pump
capacity. Replacing a dirty filter.
1. Unscrew the filter cap (1). Remove the
filter (2).
2. Wash the filter (2) carefully with a
brush under clear running water. Do
not use any abrasive cleaning agents
or solvents.
3. Reinsert the filter (2) and screw the filter
cap (1) back on.
All other measures, particularly opening
the pump (6) must be carried out by a qua-
lified electrician.
Always contact our service centre in the
case of repairs.

Storage

Store the device in a clean condition in
a dry place, out of reach of children.
To store, open the drain screw (10)
and empty the water from the pump.
Retighten the drain screw (10).