GB
IE
This device is not suitable for commercial
use. The warranty is void in the case of
commercial use.
The operator or user is responsible for any
accidents or personal injury and/or materi-
al damage to third parties or their property.
The manufacturer is not liable for damage
caused by improper use or incorrect ope-
ration.
General description
An illustration of the most im-
portant functional components
can be found on the fold-out
page.
Scope of delivery
Carefully remove the device from the pa-
ckaging and check whether all the parts
listed below are present and complete:
•
Device
•
Special key
•
Backflow stop
•
Adapter for 1¼" hose connection
•
Instruction manual
Dispose of the packaging material
properly.
Overview
1 Filter cap
A
2 Water particle filter
3 Covering cap
4 Water outlet
5 Carrying handle
6 Pump
7 Pressure accumulator
8 Drillhole for fixed installation
9 Mains connection cable
10 Drain screw
11 Pressure gauge
16
12 Automatic switch
13 Pressure hose
14 Water inlet
15 On/Off switch
16 Protective cap for air valve
17 Air valve
18 Special key
19 Backflow stop
20 Adapter for 1¼" hose
connection
Description of functions
The domestic water system automatically
transports water. The pump switches on
depending on the pressure and transports
water.
The switch-on point is factory-set to
1.5 bar (0.15 MPa).
The cut-off pressure is factory-set to 3 bar.
This is a discharge head of 30 metres. The-
se settings allow the system to achieve the
highest efficiency in terms of performance
and longevity. The cut-off pressure is ad-
justable. With a cut-off pressure of 5 bar,
the device achieves a discharge head of
50 metres. This adjustment may only be
carried out by a specialist (plumbing).
Please refer to the descriptions below for
information on how the operating elements
work.
Technical data
Domestic Water
Pump ....................PHWW 1200 A1
Nominal input voltage ...... 230 V~, 50 Hz
Power consumption ....................1200 W
Weight ...................................... 14,7 kg
Tank volume .................................... 24 l
Suction height ..........................max. 8 m
Maximum flow rate (Qmax) ...... 5000 l/h*
Maximum discharge
head - pump (Hmax) ....................50 m*