15.4 replacing the protective anode

When replacing the anode, take great care not to screw the
»
pressure switch on too tightly.
Spanner size for the anode:
— SHD 30 S - SW 13
— SHD 100 S - SW 27
Torque: 1 +0.5 Nm (finger-tight)
The transition resistance between the protective anode and
cylinder connector must be no more than 1.0 Ω.

15.5 Descaling the flange

Only descale the flange after disassembly and never treat the
»
cylinder surface and protective anode with descaling agents.

15.6 anti-corrosion protection

Ensure when carrying out service work that the anti-corrosion
protection on the insulating plate is not damaged or removed.
Reinsert the anti-corrosion protection correctly after replacement.