installation
installation
9.
Installation
9.1
Installation location
The appliance is exclusively designed for installation on a solid
wall. Ensure the wall offers adequate load bearing capacity.
Always install the appliance vertically in a room free from the risk
of frost and near to a hot water draw-off point.
9.2
Installation
9.2.1 Securing the mounting bracket
You can use the installation template to transfer the dimensions
»
to the wall.
Drill the holes and secure the mounting bracket with screws and
»
rawl plugs. Select fixing materials in accordance with the wall
construction/condition.
You can compensate for unevenness in the wall with the 5mm
thick spacers.
2
1
1 Lower spacer
2 Upper spacer
9.2.2 Preparing the power cable
120
20
|sHd s
270
9.2.3 Installing the safety assembly
Risk of damage
!
Carry out all water connection and installation works
in accordance with regulations.
Install the safety assembly. Be sure to choose the appropriate
»
safety assembly, according to the relevant static pressure.
Size the drain so that water can drain off unimpeded when the
»
safety valve is fully opened. The blow-off aperture of the safety
valve must remain open towards the atmosphere.
Fit the blow-off line of the safety assembly with a constant slope.
»
Observe the information in the installation instructions of the
»
safety assembly.
9.2.4 Mounting the appliance
1
1 Cap
Fit the caps.
»
WWW.stieBel-eltron.com