9.2.6 Completing the installation process
In single circuit and dual-circuit operation, you can adjust the
temperature selection limitation.
3
2
1 Temperature selector
2 The temperature limit can be adjusted to 45 °C, 55 °C or 65 °C.
3 Factory setting 85 °C
Replace the bottom cap.
»
Insert the screws.
»
Replace the temperature selector.
»
Connect the safety assembly with the appliance by securing the
»
pipes to the appliance with screws.
22
|sHd s
10. Commissioning
1
Open the DHW valve until the appliance has filled up and the
»
pipes are free of air.
Adjust the flow rate. Be aware of the maximum permissible
»
flow rate with a fully opened tap (see chapter "Specification /
Specification"). If necessary reduce the flow rate at the butterfly
valve of the safety assembly.
Turn the temperature selector to maximum temperature.
»
Switch the mains power ON.
»
Check the function of the appliance. Ensure that the thermostat
»
switches off.
Check the function of the safety assembly.
»
11. Taking the appliance out of use
Disconnect the appliance from the mains at the MCB/fuse in
»
the fuse box.
Drain the appliance. See chapter "Maintenance / draining
»
the appliance".
12. Recommissioning
See also chapter "Commissioning".