4.3 Electrical Connections
THE PUMP IS FACTORY EQUIPPED WITH THE COMMON
ELECTRICAL PLUG FOR A GIVEN VOLTAGE, ALTERING
THE PLUG TYPE SHOULD ONLY BE DONE BY A QUALIFIED
ELECTRICIAN, ADHERING TO ALL APPLICABLE LOCAL AND
NATIONAL CODES.
1.
The disconnect and line circuit protection to be provided by
customer. Line circuit protection to be 115% of motor full load
current at maximum pressure of application (see Figure 1).
2.
For
more
information,
for power rating.
4.4 Oil Level
Check the pump oil level prior to start-up. If oil level is low, remove
the oil fi ll plug (A) from the cover plate (see Figure 2) and add oil
as required. The reservoir is full when the oil level is as shown in
Figure 4.
Tank is full when
oil level is here.
4 and 8 liter
Figure 4, Sight Glass
IMPORTANT: Add oil only when all system components are fully
retracted, or the system will contain more oil than the reservoir can
hold. Use only Enerpac HF oil.
4.5 Hydraulic Connections
Figure 5
5 Gal. (20 L)
10 Gal. (40 L)
in. (mm)
in. (mm)
15.6 (396)
18.9 (480)
12.0 (305)
12.0 (305)
B
refer
to
pump
name
10 to 40 liter
Apply 1-1⁄2 wraps of Tefl on tape
or other suitable sealant to the
hydraulic hose fi tting, leaving the
fi rst complete thread free of tape
or sealant as shown in Figure 5.
Thread hose(s) into outlet port(s) of the valve (see valve body for
port identifi cation).
Advance hose to valve port "A".
Retract hose to valve port "B" (if applicable).
Gauge to valve port "GA", "GB", or "GP".
("GA" measures "A" port pressure, "GB" measures "B" port pressure,
"GP" measures pump pressure down stream of system check).
5.0 OPERATION
1.
Check the oil level of pump and add oil if necessary.
2.
Make sure that the reservoir air breather has been installed.
(see section 4.1)
3.
•
Model VM22 only: Place valve handle in the retract
position.
•
Models VM33M and VM43M: Place valve handle in the
neutral position.
•
Model VM43-LPS only: Place valve handle in the
neutral/hold position.
4.
Connect unit to power.
5.
For valve and motor operation instructions, see sections
5.1 – 5.3.
NOTE: Oil fl ow is controlled by a manual valve. The motor is
controlled by a switch on the pump, or by a pendant.
5.1 MANUAL VALVE OPERATION
VM22
(See Figure 6)
1. Advance
2. Retract
plate
Pump Motor Switch =
Toggle Motor On or Off .
VM33M, VM43M,
(See Figure 7)
1. Advance
2. Retract
3. Neutral
Pump Motor Switch =
Toggle Motor On or Off
VM43-LPS
(See Figure 8)
1. Advance/Stressing
2. Retract/Seating
3. Neutral/Hold
Pump Motor Switch =
Toggle Motor On or Off
NOTE: Handle position for VM33M, VM43M and VM43-LPS can
be changed if desired.
3
2
1
Figure 6
2
B
A
3
1
Figure 7
A
B
1
2
3
Figure 8