UK
10. Installer information
Function
Protection against too
low or too high ambient
temperature
Failure of the water tem-
perature sensor
Failure of the ambient
temperature sensor
General error
Water flow failure
Protection against water
pressure
10.1 Wiring diagram
The electrical wiring diagram
is only for general reference.
The swimming pool heat
pump must be connected to
the ground wire, although
heat exchanger unit is elec-
trically isolated from the rest
of the unit. The unit must still
be earthed in order to protect
against short circuits inside
the unit. Bonding is also re-
quired.
A power switch should be
located within sight and be
easily accessible from the
heat pump. This is common
practice on commercial and
residential heat pumps. It al-
lows you to turn off the power
to the unit while it is in oper-
ation.
86
Code
Reason
Ambient temperature is out of tem-
P0
perature range, 7°C-42° C.
Short circuit/open circuit of the
P1
water temperature sensor.
Short circuit/open circuit of the
P2
ambient temperature sensor.
Water flow failure or pressure pro-
EL
tection.
1. Water flow switch failure.
FL
2. No or insufficient water flow.
1. The pressure is too high or
too low.
PL
2. Failure or disconnected high/
low pressure switch.
3. Gas leakage
Solution
Before restarting the heat pump
make sure that the ambient tempera-
ture is above 9°C and below 40°C.
Replace the water temperature sen-
sor.
Replace the ambient temperature
sensor.
1. Change the water flow switch.
2. Check the water pump or if the
system is clogged.
Consult with a service technician.