The factory supplies only the heat pump itself. All other components, including a bypass if neces-
sary, must be provided by the user or the installer.
Attention:
Please observe the following rules when installing the heat pump:
Any dosing of chemicals must take place in the piping located downstream from the heat
pump.
Install a bypass in all installations.
Always place the heat pump on a solid foundation and use the included rubber mounts
to avoid vibration and noise.
Always keep the heat pump upright. If the unit has been held at an angle, wait at least 24
hours before starting the heat pump.
For optimum operation, three factors must be met:
• Good ventilation
• Stable and reliable power supply
• Good water circulation (Filter system)
Unlike gas heaters, using a heat pump does not cause any environmental pollution or have any
installation problems when exposed to wind.
4.1. Location of the heat pump
The heat pump must not be installed in an
area with limited air ventilation, or be locat-
ed in a bush where the air inlet is blocked.
Such a location would prevent a continuous
supply of fresh air. Fallen leaves can be
sucked into the heat pump and both affect
the efficiency of the heat pump and shorten
its lifespan.
Ensure that the pool's circulation pump is
placed significantly lower than the water
line, so as to create a good flow to the
heat pump. The circulation pump should
preferably be at the same level as the bot-
tom of the pool. Fig. 1 shows the minimum
required distance on each side of the heat
pump.
The heat pump must be installed no
more than 7.5 metres from the side of
the pool.