4.5. The fitting of accessories

A
B - C
Comes with:
4 vibration pads
2 drainage diverters
2 drain hose
Position the supplied anti-vibration pads (A) as shown in the picture.
If you would like to drain condensate through the hose, you can install the included drainage divert-
er (B).
The drainage (C) in the side is for the heat exchanger. Use it when the temperature is low to pre-
vent icing and damage of the heat exhanger.
IMPORTANT: Raise the heat pump. If you tip it over or turn it, you can damage the compressor.

4.6. Wiring

Power Supply Wiring
80
A
A
B
A
A
C
1) Connect the power supply
wire to cable connector (10.3
part nr. 13) as shown in the
picture.
2) Fix the other side of the
ca ble on joints inside the
electric box (10.3 part nr.
25).
Control Box Wiring
If you are the owner of a
control box. Connect to the
heat pump by wiring what is
marked in red.
MV-1400-10-2021 . © Alle rettigheder forbeholdes Swim & Fun A(S