• The function of all safety components must be checked.
• Check that all metal elements are correctly earthed.
• The power connection and fitting of the electric power cable must be checked
Important:
Incorrect installation can cause overheating and will void the warranty.
3. Display Controller
When the heat pump is running, the display shows the water inlet temperature.
LED 1 lights up when compressor is running.
LED 2 lights up if malfunction occurs.
3. Starting and Stopping the heat pump
Turn on the filter pump, check for water leaks and check the water flow of the swimming pool.
Press A to turn on the heat pump. The display shows the water setting temperature for 5 sec-
onds and then the water inlet temperature. Press A to turn off the heat pump.
4. Set the water temperature
Press B or C in order to adjust the water temperature between 10-42 °C.
Press A to save the setting.
Note
The heat pump can only run if the water circulation/filter system is running.
5. Parameter checking
The parameter checking helps showing the settings of the heat pump
Press A then press B or C, this will display the code "d0" or "d1".
d0 = Ambient temperature
d1 = Water temperature
If you see "d0" and press A, the ambient temperature will show. If you chose "d1" and press A, the
water temperature will show instead.
MV-1400-10-2021 . © Alle rettigheder forbeholdes Swim & Fun A/S
UK
B
C
A
B
C
A
83