6 Cleaning and maintenance
6.6 Changing the chemical product
Crystallisation can occur as a result of mixing different chemical products, which can dam-
age the dosing device.
Therefore, the dosing device and the dosing hoses must be flushed with water before a
new chemical product is used.
Remove the suction tube from the container and place it in a water-filled container.
Ø
Access the following menu (see the front fold-out page):
Ø
1
Press button 1 or 2.
Ø
ð The button turns white, and the dosing device is activated.
ð The dosing hoses and the dosing device are rinsed out with water.
As soon as the button goes dark, place the suction tube into the new canister.
Ø
Press button 1 or 2 again.
Ø
ð The button turns white, and the dosing device is activated.
ð The water in the dosing hoses and dosing device is replaced by the new chemical
product.
In addition, the dosage must also be reset.
To attain good wash results, commission an authorised service technician.
Ø
50
2
|
12019630/01; 2022-01
Item Name
1
Rinse aid dosing device
2
Detergent dosing device
Press button 1 or 2.
Ø
ð The button turns white.
ð The dosing device is being vented.
As soon as the button turns dark again,
Ø
exit the menu.
|
Quick guide PTD 901