2.10 Technical data

Name
Rack dimensions
Tank capacity
Noise emission
Splash guard
Minimum flow pressure PTD 901, PTD 901 LIFT
Max. inlet pressure
(Back pressure)
Flow rate
Inlet water temperature PTD 901, PTD 901 LIFT
Exhaust air
Observe local guidelines, e.g. DIN EN 16282 / VDI guideline 2052 when constructing the
ventilation system.
Operating conditions
Name
Temperature at the installation site
Relative air humidity at the installation site
Storage temperature
Max. height of the installation location above
sea level
Quick guide PTD 901
Note
Measurement uncertainty
PTD 901 ECO, PTD 901 LIFT ECO
PTD 901 ECO, PTD 901 LIFT ECO
|
12019630/01; 2022-01
2 Machine description
Unit
mm
l
dB(A)
dB
kPa
(bar)
kPa
(bar)
l/min
° C
Unit
°C
%
°C
m
|
|
English
Value
500 x 500
35
max. 62
2.5
IP X5
100 (1.0)
150 (1.5)
1000 (10.0)
min. 4
max. 60
max. 20
Value
0 - 40
< 95
> -25
2000
35