Download Inhoudsopgave Inhoud Print deze pagina

Technical Data; Cleaning And Maintenance - Sandrigarden SG 1150 Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 44
6.7 Quick-release coupling (7)
Connect
Push the nipple on your compressed air hose
into the quick-release coupling, the sleeve will
automatically spring forwards.
Disconnect
Pull back the sleeve and remove the hose.
Important ! As you release the hose
coupling, hold the hose coupling part
in your hand to prevent injuries caused by the
hose being thrown backwards.
6.8 Adjusting the pressure: (Fig. 10)
You can adjust the pressure on the pressure
gauge (13) using the pressure regulator (6).
The set pressure can be taken from the quick-lock
coupling (7).
The tank pressure can be read on the pressure
gauge (8).
6.9 Pressure switch adjustment
The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar

7. Technical data

Power supply
Motor rating
Compressor speed
Operating pressure
Pressure vessel volume
Theoretical intake rate
Sound power level LWA
Sound pressure level LpA
Protection type
Machine weight
16
OPERATING INSTRUCTIONS
230 ~ 50 Hz
1.5 kW
2800 rpm
max. 8 bar
50 litre
190 l/mim
95 dB
(K
=3,0)
LwA
74 dB
(K
=3,0)
LpA
20 IP
35 kg

8. Cleaning and maintenance

IMPORTANT!
Pull the power plug before doing any cle-
aning and maintenance work on the appliance.
IMPORTANT!
Wait until the compressor has completely
cooled down.
Risk of burns!
IMPORTANT!
Always depressurize the tank before
carrying out any cleaning and maintenance work.
To do so, connect the supplied blowout pistol to
the compressed air hose with the quick-lock cou-
pling (7). Then actuate the blow-out pistol until no
more air is blown out and the pressure gauge (8)
indicates a complete decrease in pressure.
8.1 Cleaning
 Keep the safety devices free of dirt and dust
as far as possible. Wipe the equipment with
a clean cloth or blow it with compressed air
at low pressure.
 We recommend that you clean the appliance
immediately after you use it.
 Clean the appliance regularly with a damp
cloth and some soft soap. Do not use cleaning
agents or solvents; these may be aggressive
to the plastic parts in the appliance. Ensure
that no water can get into the interior of the
appliance.
 You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
8.2 Condensation water
The condensation water must be drained off each
day by opening the drain valve (17) (on the floor
of the pressure vessel) (fig.15).

Advertenties

Inhoudsopgave
loading

Inhoudsopgave