CAUTION: Connecting brown or brown/white wires to negative battery terminals will result in
pump failure. Install all brown wires to positive terminal only and black to negative terminal only.
On 12 volt pump: Minimum voltage of 10.5 volts required.
On 24 volt pump: Minimum voltage of 21 volts required.
WARNING: Electrical connections
should be performed by a competent marine
electrical technician.
CAUTION: Disconnect power from the
system before working on the unit to avoid
personal injury, damage to the surrounding
environment and/or damage to the unit.
CAUTION: Always install proper fuse size to
prevent damage to product should a short occur.
Failure to install proper fuse could increase risk
of pump malfunction potentially resulting in
personal injury and/or fire hazard.
CAUTION: Keep all wire connections
above the highest water level. Wires must be
joined with butt connectors and a marine grade
sealant to prevent wire corrosion.