Property damage
The appliance is designed for undersink installation.
u During installation, the water connections on the
appliance must point upwards.
3.3

Structure of the warning notices

3.3.1 Section-specific warning notices
Section-specific warning notices apply to all steps in the section.
Injury
CAUTION
Type and source of risk
Consequence(s) of failure to observe the warning no-
tice
u Hazard prevention measure(s)
Property damage, consequential losses, environmental
pollution
Type and source of risk
Consequence(s) of failure to observe the warning no-
tice
Hazard prevention measure(s)
3.3.2 Embedded warning notices
Embedded warning notices apply only to the subsequent step.
u SIGNAL WORD: Consequence(s) of failure to observe the
warning notice. Hazard prevention measure(s). Step to
which the warning notice refers
3.3.3 Key to symbols
Symbol
Type of risk
Injury
Electrocution
Burns, scalding
3.3.4 Signal words
Signal
Meaning
word
DANGER
Failure to observe this information will result in death or
serious injury
WARNING Failure to observe this information may result in death or
serious injury
CAUTION
Failure to observe this information may result in moderate
or minor injury
NOTICE
Failure to observe this information may result in property
damage, consequential losses or environmental damage
www.stiebel-eltron.com
NOTICE
NOTICE

Appliance description

4
Appliance description
4.1

Function

The open vented (non-pressurised) appliance is only suitable for
undersink installation. The appliance is intended to heat cold
water for supplying a single draw-off point. It must only be used
with a non-pressurised tap.
Thermostop function
The thermostop function (thermal separation) prevents the tap
becoming hot in standby mode.
4.2

Standard delivery

The following are delivered with the appliance:
– Wall mounting bracket
– Installation template
– Angle valve with SNU 10 Plus (GB)
4.3

Required accessories

A non-pressurised tap must be used for open vented operation
of the appliance. Stiebel Eltron offers a wide range of suitable
taps.
5

Installation (qualified contractors)

5.1

Installation site

Property damage
The water in the appliance may freeze and damage
the cylinder and connections by expansion.
u Only install the appliance in a room free from the
risk of frost.
Property damage
u Mount the appliance on the wall. The wall must
have sufficient load bearing capacity.
Property damage
The appliance is designed for undersink installation.
u During installation, the water connections on the
appliance must point upwards.
Ensure that the appliance is freely accessible for
maintenance work.
Always install the appliance vertically and near the draw-off
point.
NOTICE
NOTICE
NOTICE
SNU 10 Plus |
13