CoolAir
• The ventilation openings must not be covered over (minimum distance from
other external attachments: 100 mm).
• Follow the vehicle manufacturer's guidelines when installing the system and
establishing the electrical connections.
I
NOTE
After installation of the system, the pre-set parameters on the system software
must be checked (chapter "Configuring the system software" on page 12).
7.2
Creating the opening (if necessary)
I
NOTE
To simplify the task of creating the opening, there is a template integrated in
the packaging of the installation kit.
➤ Create an opening measuring 500 mm x 400 mm with rounded corners with
a radius of R25 (fig. 6 and fig. 7, arrow = forward direction).
I
NOTE
Dispose of all waste materials separately. When doing so, follow the waste
disposal requirements applicable in your local area.
7.3
Preparing the unit
A
NOTICE! Damage hazard
When preparing the unit on the work surface, make sure it is secured against
falling off.
Make sure that the work surface is clean and level to ensure that the unit is not
damaged.
Proceed as follows (fig. 8):
➤ Place the parking cooler on a work surface with the casing facing down.
➤ Screw the 4 self-tapping M6 threaded plugs into the blind holes marked "7".
Use a 5 mm hexagon bit to do so.
➤ Screw the 4 self-tapping M8 threaded plugs into the blind holes marked "6".
To do so, use the 1/4" bit supplied.
EN
Installation
9