Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may not be used as a holding handle. A
separate handle must be installed.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
31472000: Safety against backflow
The product is exclusively designed for drinking water!
Fault
Mixer stiff
Mixer dripping
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
Diverter not operating
4
English
Symbol description
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Crossflow
- Residue
- Water pressure to low
- Diverter defective
Assembly see page 10
Do not use silicone containing acetic acid!
Adjustment (see page 12)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Dimensions (see page 13)
Flow diagram
(see page 13)
Rate of flow by 0,3 MPa:
Shower outlet
Tub outlet
Operation (see page 14)
Maintenance (see page 15)
31472000: The safety device must be
checked regularly according to DIN EN
1717 in accordance with national or re-
gional regulations (at least once a year).
Cleaning
see enclosed brochure.
Spare parts (see page 17)
Test certificate (see page 20)
Remedy
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Exchange cartridge
- Clean converter / grease O-rings
- Increase water pressure
- Exchange diverter