All manuals and user guides at all-guides.com
Environmental specifications
Operating altitude
2000 meter (7000 feet)
Drop test
2 meters (6.5 feet)
Enclosure
Double molded, waterproof
Category
IV 600 V / III 1000V
Standards
Complies with EN 61010-1 and IEC
61010-1 2
61010-1, 2
C22.2 No. 61010-1 2
61010B-2-031, 1
Pollution degree
2
Electrical specificatiions
Function
Range
DC voltage
400 mV
4 V
40 V
400 V
1000 V
AC voltage
400 mV
4 V
40 V
400 V
1000 VAC
AC+ DC voltage
400 mV
4 V
40 V
400 V
1000 V
All AC voltage ranges are specified from 5 % of
range to 100% of range
DC current
400 μA
4000 μA
40 mA
400 mA
10 A
20 A: 30 sec max with reduced accuracy
edition (2001), meets UL
nd
edition (2004), CAN/CSA
nd
edition (2004), UL
nd
edition (2003)
st
Resolution
Accuracy
0.01 mV
0.0001 V
+ (0.06 % + 4 d)
0.001 V
0.01 V
0.1 V
+ (0.1 % + 5 d)
50 ...1000 Hz
0.1 mV
+ (1.0 % + 7 d)
0.001 V
0.01 V
0.1 V
+ (1.0 % + 5 d)
1 V
0.1 mV
0.001 V
+ (1.0 % + 7 d)
0.01 V
50/60 Hz
0.1 V
1 V
0.01 μA
0.1 μA
0.001 mA
+ (1.0 % + 3 d)
0.01 mA
0.001 A
61
www.nieaf-smitt.com
Nieaf-Smitt is a brand name of Mors Smitt