5.4 mV voltage measurement

CAUTION: Do not measure mV voltages if a
motor on the circuit is being switched ON or
OFF. Large voltage surges may occur that can
damage the meter.
1. Set the function switch to the
2. Press the MODE button to indicate 'DC' or 'AC' or in
AC range press EXIT for two seconds and chose
'AC+DC'
3. Insert the black test lead banana plug into the
negative COM jack
4. Insert the red test lead banana plug into the positive
V jack
5. Touch the black test probe tip to the negative side of
the circuit
6. Touch the red test probe tip to the positive side of
the circuit
7. Read the mV voltage in the display
green
mV position
49
www.nieaf-smitt.com