5.5 DC current measurement

WARNING: Do not make 20 A current
measurements for longer than 30 seconds.
measurements for longer than 30 seconds.
Exceeding 30 seconds may cause damage to
Exceeding 30 seconds may cause damage to
the meter and the test leads.
the meter and the test leads.
1. Insert the black test lead banana plug into the
negative COM jack
2. For current measurements up to 4000 µA DC, set the
function switch to the
the red test lead banana plug into the µA/mA jack
3. For current measurements up to 400 mA DC, set the
function switch to the
the red test lead banana plug into the µA/mA jack
4. For current measurements up to 20 A DC, set the
function switch to the
insert the red test lead banana plug into the 10 A
jack
5. Press the MODE button to indicate 'DC' on the display
6. Remove power from the circuit under test, then open
up the circuit at the point where you wish to measure
current
7. Touch the black test probe tip to the negative side of
the circuit
8. Touch the red test probe tip to the positive side of
the circuit
9. Apply power to the circuit
10. Read the current in the display
Nieaf-Smitt is a brand name of Mors Smitt
50
www.nieaf-smitt.com
blue
µA position and insert
blue
mA position and insert
blue
10 A/Hz/% position and