Drive Information (Gegevens Frequentieregelaar) - Danfoss VLT HVAC Basic Drive FC 101 Handleiding

Verberg thumbnails Zie ook voor VLT HVAC Basic Drive FC 101:
Inhoudsopgave

Advertenties

Parameterlijsten
Para
Parameter description
meter
num
ber
14-21
Automatic Restart Time
14-22
Operation Mode
14-23
Typecode Setting
14-27
Action At Inverter Fault
14-28
Production Settings
14-29
Service Code
14-3* Current Limit Ctrl.
14-30
Current Lim Ctrl, Proportional Gain
14-31
Current Lim Ctrl, Integration Time
14-32
Current Lim Ctrl, Filter Time
14-4* Energy Optimising
14-40
VT Level
14-41
AEO Minimum Magnetisation
14-44
d-axis current optimization for IPM
14-5* Environment
14-50
RFI Filter
14-51
DC-Link Voltage Compensation
14-52
Fan Control
14-53
Fan Monitor
14-55
Output Filter
14-6* Auto Derate
14-61
Function at Inverter Overload
14-63
Min Switch Frequency
Dead Time Compensation Zero
14-64
Current Level
Speed Derate Dead Time Compen-
14-65
sation
14-9* Fault Settings
14-90
Fault Level

5.1.12 15-** Drive Information (Gegevens frequentieregelaar)

Para
Parameter description
meter
num
ber
15-0* Operating Data
15-00
Operating hours
15-01
Running Hours
15-02
kWh Counter
15-03
Power Up's
15-04
Over Temp's
15-05
Over Volt's
15-06
Reset kWh Counter
15-07
Reset Running Hours Counter
15-3* Alarm Log
15-30
Alarm Log: Error Code
15-31
InternalFaultReason
15-4* Drive Identification
MG18B510
Programmeerhandleiding
Default value
4 set-up
10 s
All set-ups
[0] Normal
operation
1 set-up
0 N/A
1 set-up
[1] Warning
All set-ups
[0] No action
1 set-up
0 N/A
1 set-up
100 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
90 %
All set-ups
66 %
All set-ups
100 %
All set-ups
[1] On
1 set-up
[1] On
All set-ups
ExpressionLimit
1 set-up
[1] Warning
1 set-up
[0] No Filter
1 set-up
[0] Trip
All set-ups
[2] 2.0 kHz
1 set-up
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
[3] Trip lock
1 set-up
Default value
4 set-up
0 h
1 set-up
0 h
1 set-up
0 kWh
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
[0] Do not reset
1 set-up
[0] Do not reset
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
Danfoss A/S © 05/2018 Alle rechten voorbehouden.
Change during
Conversion
operation
index
TRUE
0
TRUE
-
FALSE
0
TRUE
-
FALSE
-
TRUE
0
TRUE
0
TRUE
-3
TRUE
-4
FALSE
0
FALSE
0
TRUE
0
FALSE
-
FALSE
-
TRUE
-
TRUE
-
FALSE
-
TRUE
-
FALSE
-
FALSE
-
FALSE
0
FALSE
-
Change during
Conversion
operation
index
TRUE
74
TRUE
74
TRUE
75
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
0
Type
Uint16
Uint8
uint8
Uint8
Uint8
Uint32
5
5
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Type
Uint32
Uint32
Uint32
Uint32
Uint16
Uint16
Uint8
Uint8
Uint8
Int16
125

Advertenties

Inhoudsopgave
loading

Inhoudsopgave