Parameterlijsten
Para
Parameter description
meter
num
ber
8-9* Bus Feedback
8-94
Bus Feedback 1
8-95
Bus Feedback 2

5.1.10 13-** Smart Logic

Para
Parameter description
5
5
meter
num
ber
13-0* SLC Settings
13-00
SL Controller Mode
13-01
Start Event
13-02
Stop Event
13-03
Reset SLC
13-1* Comparators
13-10
Comparator Operand
13-11
Comparator Operator
13-12
Comparator Value
13-2* Timers
13-20
SL Controller Timer
13-4* Logic Rules
13-40
Logic Rule Boolean 1
13-41
Logic Rule Operator 1
13-42
Logic Rule Boolean 2
13-43
Logic Rule Operator 2
13-44
Logic Rule Boolean 3
13-5* States
13-51
SL Controller Event
13-52
SL Controller Action

5.1.11 14-** Special Functions (Speciale functies)

Para
Parameter description
meter
num
ber
14-0* Inverter Switching
14-01
Switching Frequency
14-03
Overmodulation
14-07
Dead Time Compensation Level
14-08
Damping Gain Factor
14-09
Dead Time Bias Current Level
14-1* Mains Failure
14-10
Mains Failure
14-11
Mains Fault Voltage Level
14-12
Response to Mains Imbalance
14-15
Kin. Back-up Trip Recovery Level
14-2* Reset Functions
14-20
Reset Mode
124
®
VLT
HVAC Basic Drive FC 101
Default value
4 set-up
0 N/A
All set-ups
0 N/A
Default value
4 set-up
[0] Off
[39] Start command
[40] Drive stopped
[0] Do not reset SLC
[0] Disabled
[1] Approx.Equal (~)
0 N/A
0 s
[0] False
[0] Disabled
[0] False
[0] Disabled
[0] False
[0] False
[0] Disabled
Default value
4 set-up
ExpressionLimit
All set-ups
[0] Off
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] No function
All set-ups
ExpressionLimit
All set-ups
[0] Trip
ExpressionLimit
All set-ups
[0] Manual reset
All set-ups
Danfoss A/S © 05/2018 Alle rechten voorbehouden.
Change during
operation
TRUE
1 set-up
TRUE
Change during
operation
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
Change during
operation
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE
TRUE
1 set-up
TRUE
TRUE
TRUE
Conversion
Type
index
0
Int16
0
Int16
Conversion
Type
index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-3
Int32
-2
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
Conversion
Type
index
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
0
Uint16
-
Uint8
-3
Uint32
-
Uint8
MG18B510

Advertenties

Inhoudsopgave
loading

Inhoudsopgave