Download Inhoudsopgave Inhoud Print deze pagina

Danfoss VLT HVAC Basic Drive FC 101 Handleiding pagina 121

Verberg thumbnails Zie ook voor VLT HVAC Basic Drive FC 101:
Inhoudsopgave

Advertenties

Parameterlijsten
Para
Parameter description
meter
num
ber
1-2* Motor Data
1-20
Motor Power
1-22
Motor Voltage
1-23
Motor Frequency
1-24
Motor Current
1-25
Motor Nominal Speed
1-26
Motor Cont. Rated Torque
1-29
Automatic Motor Adaption (AMA)
1-3* Adv. Motor Data
1-30
Stator Resistance (Rs)
1-33
Stator Leakage Reactance (X1)
1-35
Main Reactance (Xh)
1-37
d-axis Inductance (Ld)
1-38
q-axis Inductance (Lq)
1-39
Motor Poles
1-4* Adv. Motor Data II
1-40
Back EMF at 1000 RPM
1-42
Motor Cable Length
1-43
Motor Cable Length Feet
1-44
d-axis Inductance Sat. (LdSat)
1-45
q-axis Inductance Sat. (LqSat)
1-46
Position Detection Gain
1-48
Current at Min Inductance for d-axis
1-49
Current at Min Inductance for q-axis
1-5* Load Indep. Setting
1-50
Motor Magnetisation at Zero Speed
1-52
Min Speed Normal Magnetising [Hz]
1-55
U/f Characteristic - U
1-56
U/f Characteristic - F
1-6* Load Depen. Setting
1-62
Slip Compensation
1-63
Slip Compensation Time Constant
1-64
Resonance Dampening
1-65
Resonance Dampening Time Constant
1-66
Min. Current at Low Speed
1-7* Start Adjustments
1-70
Start Mode
1-71
Start Delay
1-72
Start Function
1-73
Flying Start
1-8* Stop Adjustments
1-80
Function at Stop
1-82
Min Speed for Function at Stop [Hz]
1-88
AC Brake Gain
1-9* Motor Temperature
1-90
Motor Thermal Protection
1-93
Thermistor Source
MG18B510
Programmeerhandleiding
Default value
4 set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Off
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
50 m
All set-ups
164 ft
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
100 %
All set-ups
100 %
All set-ups
100 %
All set-ups
1 Hz
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 %
All set-ups
0.1 s
All set-ups
100 %
All set-ups
0.005 s
All set-ups
50 %
All set-ups
[1] Parking
All set-ups
0 s
All set-ups
[2] Coast/delay time
All set-ups
ExpressionLimit
All set-ups
[0] Coast
All set-ups
0 Hz
All set-ups
1.4 N/A
All set-ups
[4] ETR trip 1
All set-ups
[0] None
All set-ups
Danfoss A/S © 05/2018 Alle rechten voorbehouden.
Change during
Conversion
operation
index
FALSE
-
FALSE
0
FALSE
0
FALSE
-2
FALSE
67
FALSE
-1
FALSE
-
FALSE
-3
FALSE
-3
FALSE
-2
FALSE
-6
FALSE
-6
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
-6
FALSE
-6
TRUE
0
FALSE
0
FALSE
0
TRUE
0
TRUE
-1
FALSE
-1
FALSE
-1
TRUE
0
TRUE
-2
TRUE
0
TRUE
-3
TRUE
0
TRUE
-
TRUE
-1
TRUE
-
TRUE
-
TRUE
-
TRUE
-1
TRUE
-1
TRUE
-
FALSE
-
Type
Uint8
Uint16
Uint16
Uint32
Uint16
Uint32
5
5
Uint8
Uint32
Uint32
Uint32
Int32
Int32
Uint8
Uint16
Uint8
Uint16
Int32
Int32
Uint16
Int16
Uint16
Uint16
Uint16
Uint16
Uint16
Int16
Uint16
Uint16
Uint16
Uint32
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint8
Uint8
119

Advertenties

Inhoudsopgave
loading

Inhoudsopgave