Analog In/Out (Analoog In/Uit) - Danfoss VLT HVAC Basic Drive FC 101 Handleiding

Verberg thumbnails Zie ook voor VLT HVAC Basic Drive FC 101:
Inhoudsopgave

Advertenties

Parameterlijsten
Para
Parameter description
meter
num
ber
5-42
Off Delay, Relay
5-5* Pulse Input
5-50
Term. 29 Low Frequency
5-51
Term. 29 High Frequency
5-52
Term. 29 Low Ref./Feedb. Value
5-53
Term. 29 High Ref./Feedb. Value
5-9* Bus Controlled
5
5
5-90
Digital & Relay Bus Control

5.1.8 6-** Analog In/Out (Analoog In/Uit)

Para
Parameter description
meter
num
ber
6-0* Analog I/O Mode
6-00
Live Zero Timeout Time
6-01
Live Zero Timeout Function
6-02
Fire Mode Live Zero Timeout Function
6-1* Analog Input 53
6-10
Terminal 53 Low Voltage
6-11
Terminal 53 High Voltage
6-12
Terminal 53 Low Current
6-13
Terminal 53 High Current
6-14
Terminal 53 Low Ref./Feedb. Value
6-15
Terminal 53 High Ref./Feedb. Value
6-16
Terminal 53 Filter Time Constant
6-19
Terminal 53 mode
6-2* Analog Input 54
6-20
Terminal 54 Low Voltage
6-21
Terminal 54 High Voltage
6-22
Terminal 54 Low Current
6-23
Terminal 54 High Current
6-24
Terminal 54 Low Ref./Feedb. Value
6-25
Terminal 54 High Ref./Feedb. Value
6-26
Terminal 54 Filter Time Constant
6-29
Terminal 54 mode
6-7* Analog/Digital Output 45
6-70
Terminal 45 Mode
6-71
Terminal 45 Analog Output
6-72
Terminal 45 Digital Output
6-73
Terminal 45 Output Min Scale
6-74
Terminal 45 Output Max Scale
6-76
Terminal 45 Output Bus Control
6-9* Analog/Digital Output 42
6-90
Terminal 42 Mode
6-91
Terminal 42 Analog Output
6-92
Terminal 42 Digital Output
6-93
Terminal 42 Output Min Scale
6-94
Terminal 42 Output Max Scale
122
®
VLT
HVAC Basic Drive FC 101
Default value
4 set-up
0.01 s
All set-ups
20 Hz
All set-ups
32000 Hz
All set-ups
0 N/A
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
Default value
4 set-up
10 s
All set-ups
[0] Off
All set-ups
[0] Off
All set-ups
0.07 V
All set-ups
10 V
All set-ups
4 mA
All set-ups
20 mA
All set-ups
0 N/A
All set-ups
ExpressionLimit
All set-ups
0.01 s
All set-ups
[1] Voltage mode
0.07 V
All set-ups
10 V
All set-ups
4 mA
All set-ups
20 mA
All set-ups
0 N/A
All set-ups
ExpressionLimit
All set-ups
0.01 s
All set-ups
[1] Voltage mode
[0] 0-20 mA
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
0 %
All set-ups
100 %
All set-ups
0 N/A
All set-ups
[0] 0-20 mA
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
0 %
All set-ups
100 %
All set-ups
Danfoss A/S © 05/2018 Alle rechten voorbehouden.
Change during
operation
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Change during
operation
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Conversion
Type
index
-2
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
0
Uint32
Conversion
Type
index
0
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
-5
Uint16
-5
Uint16
-3
Int32
-3
Int32
-2
Uint16
-
Uint8
-2
Uint16
-2
Uint16
-5
Uint16
-5
Uint16
-3
Int32
-3
Int32
-2
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
0
Uint16
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
MG18B510