Overheat protection
Inside the toilet there is a resettable overheating protector. If the overheating protection is trigge-
red, check the following:
1. The bag doesn't fall down completely and is caught by the incineration chamber lid
2. There is an obstruction in the ventilation pipe
3. The toilet is incorrectly installed
4. The resistance in the ventilation pipe is too high
5. There is a malfunction in the flushing mechanism
Always try to find the cause of the overheating protection triggered. if none of the above was the
cause of triggering the overheat protection, contact your reseller.
Over-load protection
Protect against changes in power, so-called voltage peaks. Works completely automatically.
Battery operation
The battery is a 12 V battery which is charged continuously. The battery becomes operational
automatically if the power supply no longer works.
Battery operation ensures that cooling, display and fan operate even in the event of a power
failure.
Ashpan
The bags in which the waste is gathered in incinerated in the ashpan. The bag falls down when the
flush handle is pushed down.
Lid to the incineration chamber
When you press down the flush handle, the lid to the incinerating chamber opens so that the bag
can fall down into the ashpan. When the flush handle moves up again the lid is closed and keeps
the heat inside the incinerating chamber.