Option 3
External installation through the wall without a 45 degree bend.
A. Connection pipe (horizontal) maximum 500 mm, install with 2 degrees inclination backwards
from the toilet. Minimum 100 mm between the toilet and the wall
B. Maximum 5 meters in total length from the 90 degree bend
C. Maximum 500 mm above the roof
Fresh air vent is placed on an outer wall. If placed directly behind the toilet, underneath the
ventilation pipe, min Ø 110 mm, if placed elsewhere min Ø 125 mm.
NOTE! Only Ø 110 mm ventilations pipes made of plastic and one pcs 90 degree bend may be used in
the installation.
Use the included
measurement sketch.
A
340 mm
Consider the following;
degrees, silicone and minimum
distance between toilet and wall.
EN-16
C
B
Min
100 mm