Programming the run times
This function is only available with MemoControl transmitters
from the Becker Centronic range of control units.
Each radio receiver can save one switching time for one UP and one DOWN
cycle.
In the "Timer" slide switch position, the UP and DOWN cycles are automatically
repeated every 24 hours.
It does not matter what position the manual/auto slide switch is in when pro-
gramming the switching time. Previously stored switching times are overwrit-
ten.
1.
To program the DOWN run time, the tubular drive must be in the upper
limit position, and to program the UP run time it must be in the lower limit
position.
2.
Wait for the time you wish the automatic drive command to be executed.
3.
At the desired time, press and hold the relevant direction button of the
MemoControl transmitter until the tubular drive briefly stops after approx.
6 seconds and then continues to the limit position.
4.
Release the direction button.
The radio receiver has saved the current time for this direction of travel.
Only clean the device with a suitable cloth. Do not use aggressive cleaning
agents that may damage the surface.
Cleaning
37 - en