Battery type setting
Set the electronic board of the machine and the battery charger according to the type of batteries installed (WET or GEL/AGM) as
shown below:
5.
Turn the ignition key (58) to "I" and, in the very Þ rst seconds of machine operation, detect the current setting by counting the
number of ß ashes of the battery warning lights (62), as shown in the following table:
SETTING
DISPLAY (71)
1
2
3
4
5
6
6.
If the setting is to be changed, perform the following procedure.
7.
Turn off the machine by turning the ignition key (58) to "0".
8.
Press and hold the switches (63) and (65) at the same time, then turn the ignition key (58) to "I".
9.
Release the switches (63) and (65) at least 5 seconds after starting the machine.
10.
Within 3 seconds, shortly press the switch (65) to go to the next setting (1 to 6 in cyclic sequence).
NOTE
When performing steps 9 and 10, the settings are shown on the display (71) too, by the code in the table.
NOTE
When using batteries with a capacity lower than 160Ah@5h (in case of doubt, refer to the battery documents), to avoid
battery overheating during charging procedure, use the REDUCED charging current with setting 4, 5 or 6 shown in the
table, according to the type of batteries installed.
NOTE
The battery charger must be set according to the type of batteries.
Battery charging
11.
Charge the batteries (see the procedure in Maintenance chapter).
9098960000(1)2011-04 A
Bedienungsanleitung auf www.gluesing.net
BATTERY WARNING LIGHT INDICATION
(62)
4 ß ashes of the red warning light
4 ß ashes of the green warning light
4 ß ashes of the yellow warning light
2 ß ashes of the red warning light
2 ß ashes of the green warning light
2 ß ashes of the yellow warning light
SCRUBTEC R 466 - R 471 - R 471C - BOOST
USER MANUAL
BATTERY TYPE
CHARGING CURRENT
WET
GEL-AGM
STANDARD
GEL EXIDE
®
type
WET
GEL-AGM
REDUCED (see note)
GEL EXIDE
®
type
®
R4
ENGLISH
13