Hopper hydraulic lifting system
Pump
Maximum pressure
Oil tank capacity
Hydraulic circuit total capacity
Hydraulic system oil (at ambient temperature above 10 °C)
CAUTION!
If the machine is to be used at ambient temperatures below +10°C, the oil should be changed with equivalent oil
having a viscosity of 32 cSt. For temperatures below 0°C, use an oil with even lower viscosity.
(*)
See the oil technical data and reference data tables below.
TECHNICAL DATA
AGIP ARNICA
Viscosity at 40°C
Viscosity at 100°C
Viscosity index
Flash point COC
Pour point
Density at 15°C
46
32
mm²/s
45
32
mm²/s
7.97
6.40
/
150
157
°C
215
202
°C
-36
-36
kg/l
0.87
0.865
SR 1300H D
USER MANUAL
Values
Parker 108 AE S32 – 12 V
110 Bar
0.75 litres
1.4 litres
AGIP Arnica 46 (*)
REFERENCE DATA
ISO-L-HV
ISO 11158
AFNOR NF E 48603 HV
AISE 127
ATOS Tab. P 002-0/I
BS 4231 HSE
CETOP RP 91 H HV
COMMERCIAL HYDRAULICS
Danieli Standard 0.000.001 (AGIP ARNICA22,46,68)
EATON VICKERS I-286-S3
EATON VICKERS M-2950
DIN 51524 t.3 HVLP
LAMB LANDIS-CINCINNATI P68, P69, P70
LINDE
PARKER HANNIFIN (DENISON) HF-0
REXROTH RE 90220-1/11.02
SAUER-DANFOSS 520L0463
146 2275 000(2)2007-02 A
ENGLISH