Warmtepompregeling
Inhoudsopgave

Advertenties

Basisinformatie
Verwarmingsspecialist - Parameterlijst
Command
Menu Selection
Line
Configuration
6290
6291
6292
6293
6294
6295
LPB
6600
6610
6640
Fault
6710
6711
Maintenance/
7070
special
7071
operating mode
7072
7073
7074
7075
7076
7077
7078
7079
7080
7081
7082
7083
7090
7091
7092
7093
7120
7141
7150
7152
7153
7167
7181
7183
7223
7300
Config extensi-
on module
Selection Option
Measurement room temp 1
Measurement room temp 2
Measurement room temp 3
Measurement rel room humidity
1
Measurement rel room humidity
2
Measurement rel room humidity
3
Device address
Display system messages
Clock mode
Reset alarm relays
Reset heat pump
HP interval
HP time since maint
Max starts compr1/hrs run
Cur starts compr1/hrs run
Max starts compr2/hrs run
Cur starts compr2/hrs run
Diff condens max/week
Cur diff condens max/week
Diff condens min/week
Cur diff condens min/week
Diff evap max/week
Cur diff evap max/week
Diff evap min/week
Cur diff evap min/week
DHW storage time interval
DHW storage since maintenance Months
DHW charge temp HP min
Curr DHW charg temp HP
Economy mode
Emergency operation
Simulation outside temp
Triggering defrost
Pumping off refrigerant
Commissioning wizard
Phone no. responsibility 1
Phone no. responsibility 2
Disable heat pump
Function extension module 1
Unit
Min.
None, with H1, with H2 module 1, with Eingang
H2 module 2, with H2 module 3, with H21 module
1, with H21 module 2, with H21 module 3, with
H22 module 1, with H22 module 2, with H22 mo-
dule 3, with H3
0
-
OFF
-
Autonomously, Slave without remote setting,
-
Slave with remote setting, Master
No
No
Months
1
Months
0
0,1
0
0,1
0
1
0
1
0
1
0
1
0
Months
1
0
°C
8
°C
8
OFF
OFF
°C
-50
No
OFF
OFF
0
0
Inactive
None, Multifunctional, Heating circuit 1, Heating
circuit 2, Heating circuit 3, Solar DHW, Primary
contr/system pump, DHW primary controller, In-
stantaneous water heater, Cooling circuit 1, Hea-
ting circ/cooling circ 1, Solid fuel boiler, Cooling
circuit 2, Heating circ/cooling circ 2, Cooling circuit
3, Heating circ/cooling circ 3, DHW interm circuit
controller
26
Factory
Max
Settings
16
1
ON
OFF
Autonomously
Yes
No
Yes
No
240
0
240
0
12
-
12
0
12
-
12
0
250
-
250
0
250
-
250
0
250
-
250
0
250
-
250
0
240
-
240
0
80
40
80
20
ON
OFF
ON
OFF
50
-
Yes
No
ON
OFF
ON
OFF
255
255
Active
Inactive