Basisinformatie
Verwarmingsspecialist - Parameterlijst
Menu Selection Command
Line
4760
Buffer storage
tank
(only if active)
4761
Buffer storage
tank
(only if active)
5007
DHW storage
tank
5060
DHW storage
tank
5090
DHW storage
tank
5700
Configuration
5710
5711
5712
5715
5716
5717
5721
5722
5723
5731
5736
5740
5750
5751
5800
5807
5808
5890
5891
5892
5894
5895
5896
5897
5898
5899
5900
5901
5902
5903
5909
Selection Option
Charg sensor el imm heater
Forced charging electric
Charging request
El imm heater optg mode
With buffer
Presetting
Heating circuit 1
Cooling circuit 1
Use of mixing valve 1
Heating circuit 2
Cooling circuit 2
Use of mixing valve 2
Heating circuit 3
Cooling circuit 3
Use of mixing valve 3
DHW ctrl elem Q3
DHW separate circuit
Output el imm heater K6
Consumer circuit 1
Consumer circuit 2
Heat source
Refrigeration
Cooling system
Relay output QX1
Relay output QX2
Relay output QX3
Relay output ZX4
Relay output QX5
Relay output QX6
Relay output QX7
Relay output QX8
Relay output QX9
Relay output QX10
Relay output QX11
Relay output QX12
Relay output QX13
Function output ZX4 mod.
Triac output
Unit
Min.
With B4, with B42/B41
No
Setpoint, With B3 ¦ With
B31
Substitute, Summer,
Always, Cooling mo-
de ,Emergency operati-
on, Legionella function
Yes
-
1
-
ON
-
OFF, 4-conductor system, 2-conductor system
-
Heating, cooling, heating and cooling
-
ON
-
Off, 4-pipe system cooling, 2-pipe system cooling
-
Heating, cooling, heating and cooling
-
On
-
Off, 4-pipe system cooling, 2-pipe system cooling
-
Heating, cooling, heating and cooling
No charging request, Charging pump, Diverting valve
-
ON
kW
0,1
Heating, 4-pipe system cooling, 2-pipe system cooling
Heating, 4-pipe system cooling, 2-pipe system cooling
Brine, Water, Air, Externally brine, Externally water, Externally air
OFF, Active and passive cooling,
Active cooling, Passive cooling
°C
4-pipe system cooling, 2-pipe system cooling
None, Compressor 2 K2, Process revers valve Y22,
Hot-gas temp K31, El imm heater 1 flow K25,
El imm heater 2 flow K26, Div valve cool sourceY28,
System pump Q14, Cascade pump Q25,
Heat gen shutoff valve Y4, El imm heater DHW K6,
Circulating pump Q4, St tank transfer pump Q11,
DHW Intermed. circ. pump Q33, DHW mixing pump Q35,
Collector pump Q5, Collector pump 2 Q16,
Solar pump ext exch K9, Solar ctrl elem buffer K8,
Solar ctrl elem swi pool K18, El imm heater buffer K16,
Cons circuit pump VK1 Q15, Cons circuit pump VK2 Q18,
Swimming pool pump Q19, HC pump HC3 Q20,
2nd pump speed HC1 Q21, 2nd pump speed HC2 Q22,
2nd pump speed HC3 Q23, Div valve HC/CC1 Y21,
Air de-humidifier K29, Heat request K27,
Refrigeration request K28, Alarm output K10,
Time program 5 K13, Heat circuit pump HC1 Q2,
DHW ctrl elem Q3, Source pump Q8/fan K19,
Condenser pump Q9, Compressor stage 1 K1,
Suppl source control K32, Heat circuit pump HC2 Q6,
Instant WH ctrl elem Q34, Common flow valve Y13,
Div valve HC/CC2 Y45, Div valve HC/CC3 Y46,
Cooling circ pump CC1 Q24, Cooling circ pump CC2 Q28,
Cooling circ pump CC3 Q29, Solid fuel boiler pump Q10
Flue gas relay K17, Assisted firing fan K30,
Crankcase heater K40, Drip tray heater K41,
Valve evaporator K81, Valve EVI K82,
Valve injection capillary K83, dT-controller 1 K21,
dT-controller 2 K22, Source int circ pump Q81,
Source int circ div Y81, DHW heat pump K33,
System pump 2 Q44, Div valve cooling cond Y27,
Div valve cooling flowY29, Cond reversing valve Y91,
Buffer reversing valve Y47, Status info heating K42,
Status info cooling K43, Status info DHW charg K44,
Heat/cool circ pump 1 Q2, Heat/cool circ pump 2 Q6
Heat/cool circ pump 3 Q20
None, Source pump Q8 / fan K19,
DHW pump Q3, DHW intermediate circuit pump Q33,
Heating circuit pump HC1 Q2, Heating circuit pump HC2 Q6
Heating circuit pump HC3 Q20, Collector pump Q5,
Solar pump external exchanger K9, Solar pump buffer K8,
Solar pump pool K18, Collector pump 2 Q16,
DHW flow heater pump Q34, Solid fuel boiler pump Q10,
Condenser pump Q9, Heating/Cooling circuit pump 1 Q2,
Heating/Cooling circuit pump 2 Q6,
Heating/Cooling circuit pump 3 Q20, Compressor modulation,
Ventilation fan 1 K51,Ventilation fan 2 K52, Ventilation fan 3 K53
23
Max
With B4, with B42/B41
With B42/B41
No
Setpoint, With B3 ¦ With
B31
Substitute
Substitute, Summer,
Always, Cooling mo-
de ,Emergency operati-
on, Legionella function
No
40
Depends on HP
OFF
OFF
Off
OFF
99
Depends on HP
Depends on HP
Depends on HP
Factory
Settings
No
Setpoint
Yes
type
0,1
Heating
Heating
Cooling
type