Basisinformatie
Verwarmingsspecialist - Parameterlijst
Command
Menu Selection
Line
Cooling
1201
circuit 2
1202
(only if active)
1203
1204
1208
1209
1212
Heating
1300
circuit 3
1310
(only if active)
1312
1314
1320
1330
1340
1341
1342
1450
1451
1456
1457
1470
1472
1500
Cooling
1501
circuit 3
1502
(only if active)
1503
1504
1508
1509
1512
Domestic hot
1610
water DHW
1612
1614
1620
1630
1640
1641
1642
1644
1645
1646
1647
1660
1661
1663
Selection Option
Operating mode
Comfort setpoint
Reduced setpoint
Protection setpoint
Flow temp setp at OT 25°C
Flow temp setp at OT 35°C
Cooling limit at OT
Operating mode
Comfort setpoint
Reduced setpoint
Protection setpoint
Heating curve slope
Summer/winter heating limit
Flow temp setpoint min
Flow temp setpoint max
Flow temp setpoint room stat
Floor curing function
Floor curing setp manually
Floor curing day current
Floor curing days completed
With buffer
With prim contr/system pump
Optg mode changeover
Operating mode
Comfort setpoint
Reduced setpoint
Protection setpoint
Flow temp setp at OT 25°C
Flow temp setp at OT 35°C
Cooling limit at OT
Nominal setpoint
Reduced setpoint
Nominal setpoint max
Release
Charging priority
Legionella function
Legionella funct periodically
Legionella funct weekday
Legionella funct time
Legionella funct setpoint
Legionella funct duration
Legionella funct circ pump
Circulating pump release
Circulating pump cycling
Circulation setpoint
Unit
Min.
Off,Protection,Automatic,Reduced,Comfort
-
°C
°C
Value from line 1202
°C
Value from line 1203
°C
°C
°C
Protection, automatic, reduced, comfort
-
°C
Value from line 1312
°C
Value from line 1314
°C
4
0.10
-
°C
---/8
°C
8
°C
Value from line 1340
8
-
OFF, function heating, Curing heating, function/Functional
-
and curing heating, Curing and functional heating, manual
°C
0
-
-
No, Yes
-
No, Yes
-
None, Protection, Reduced, Comfort, Automatic
-
Off,Protection,Automatic,Reduced,Comfort
-
°C
5
°C
Value from line 1502
°C
Value from line 1503
8
°C
8
°C
°C
8
°C
Value from line 1612
°C
8
°C
Line 1610
24h/day, All time programs HC/CC, Time program 4/DHW,
-
Low-tariff, T'prog 4/DHW or low-tariff
Absolute, Shifting, None, MC shifting, PC absolute
-
OFF, Periodically, fixed weekday
-
Days
1
Monday, Tuesday, Wednesday, Thursday, Friday, Saturday,
-
Sunday
hh:mm
---/00:00
°C
55
min
---/10
ON
-
Timer program HC3//CC3, DHW release,
-
timer program 4/DHW, timer program 5
ON
-
°C
8
20
Max
5
8
8
8
35
Value from line 1310
Value from line 1312
4.00
30
Value line 1341
95
95
95
40
Value from line 1504
40
35
35
35
55
Value from line 1610
80
Timer program 4 PWP
Depends on HP type
7
23:50
95
360
OFF
Timer program 5
OFF
80
Factory
Settings
Automatic
24
26
35
20
24
24
Automatic
20.0
16.0
10.0
0.8
20
8
50
-
OFF
25
0
0
Yes
Yes
Protection
Automatic
24
26
35
20
24
24
50
45
65
OFF
3
Monday
---
65
30
ON
ON
45