Warmtepompregeling
Inhoudsopgave

Advertenties

Basisinformatie
Verwarmingsspecialist - Parameterlijst
Command
Menukeuze
Menu Selection
Line
Heating circuit 1
710
712
714
720
730
740
741
742
850
851
856
857
870
872
900
Cooling circuit 1
901
902
903
904
908
909
912
Heating circuit 2
1010
(only if active)
1012
1014
1020
1030
1040
1041
1042
1150
1151
1156
1157
1170
1172
1200
Cooling
1201
circuit 2
1202
(only if active)
1203
1204
1208
1209
1212
Selection Option
Comfort setpoint
Reduced setpoint
Protection setpoint
Heating curve slope
Summer/winter heating limit
Flow temp setpoint min
Flow temp setpoint max
Flow temp setpoint room stat
Floor curing function
Floor curing setp manually
Floor curing day current
Floor curing days completed
With buffer
With prim contr/system pump
Optg mode changeover
Operating mode
Comfort setpoint
Reduced setpoint
Protection setpoint
Flow temp setp at OT 25°C
Flow temp setp at OT 35°C
Cooling limit at OT
Comfort setpoint
Reduced setpoint
Protection setpoint
Heating curve slope
Summer/winter heating limit
Flow temp setpoint min
Flow temp setpoint max
Flow temp setpoint room stat
Floor curing function
Floor curing setp manually
Floor curing day current
Floor curing days completed
With buffer
With prim contr/system pump
Optg mode changeover
Operating mode
Comfort setpoint
Reduced setpoint
Protection setpoint
Flow temp setp at OT 25°C
Flow temp setp at OT 35°C
Cooling limit at OT
Unit
Min.
°C
Value from line 712
°C
Value from line 714
°C
4
0.10
-
°C
---/8
°C
8
°C
Value from line 740
°C
8
OFF, function heating, Curing heating, function/Functional
-
and curing heating, Curing and functional heating, manual
°C
0
-
No, yes
-
No, yes
-
None, Protection, Reduced, Comfort, Automatic
-
OFF
-
°C
5
°C
Value from line 902
°C
Value from line 903
°C
8
°C
8
°C
8
°C
Value from line 1012
°C
Value from line 1014
°C
4
0.10
-
°C
---/8
°C
8
°C
Value from line 1040
8
-
OFF, function heating, Curing heating, function/Functional
-
and curing heating, Curing and functional heating, manual
°C
0
-
-
No, Yes
-
No, Yes
-
None, Protection, Reduced, Comfort, Automatic
-
Off,Protection,Automatic,Reduced,Comfort
-
°C
5
°C
Value from line 1202
°C
Value from line 1203
8
°C
°C
8
°C
8
19
Factory
Max
Settings
35
Value from line 710
Value from line 712
4.00
30
Value from line 741
95
95
95
Protection
Automatic
Automatic
40
Value from line 904
40
35
35
35
35
Value from line 1010
Value from line 1012
4.00
30
Value from line 1041
95
95
95
Protection
Automatic
40
Value from line 1204
40
35
35
35
20.0
16.0
10.0
0.8
20
8
50
50
OFF
25
0
0
24
26
35
20
24
24
20.0
16.0
10.0
0.8
20
8
50
-
OFF
25
0
0
Yes
Yes
24
26
35
20
24
24