Area
PowerSet Description
15.6 m²
PowerSet Mini 2.0-170-1p
18.2 m²
PowerSet Turbo 2.4-170-1p
23.4 m²
PowerSet Turbo 3.0-165-1p
23.4 m²
PowerSet Turbo 3.1-170-1p
23.4 m²
PowerSet Turbo 3.1-170-3p
26.0 m²
PowerSet Turbo 3.4-170-1p
27.3 m²
PowerSet Turbo 3.6-170-1p
31.2 m²
PowerSet Turbo 4.0-165-1p
31.2 m²
PowerSet Turbo 4.1-170-1p
31.2 m²
PowerSet Turbo 4.1-170-3p
36.4 m²
PowerSet Turbo 4.8-170-1p
39.0 m²
PowerSet Turbo 5.1-170-3p
45.5 m²
PowerSet Turbo 6.0-170-3p
54.6 m²
PowerSet Turbo 7.1-170-3p
62.4 m²
PowerSet Turbo 8.2-170-1p
Accessories configured for the PowerSets are separately available from Solar Frontier: DC cables, mounting and fastening material, tools for assembly of the cables...
Schematic structure based on PowerSet Turbo 3.1
example
PV Generator
DC-Cable with plug and socket
4.

About this Manual

4.1

Contents

These instructions contain all information required by a technical professional for
setting up and operating the inverters.
When installing other components (e.g., AC cable, mounting system) follow the
manufacturer's instructions.

4.2 Target audience

Unless otherwise indicated, the target audiences of this manual are technical
professionals and system operators.
Technical professionals are persons who, for example:
have the knowledge of terminology and the skills necessary for setting up and
operating photovoltaic systems;
because of their professional training, knowledge and experience and knowl-
edge of the relevant regulations can assess the following tasks and recognise
possible dangers:
- mounting electrical devices
- assembling and connecting data cables
- assembling and connecting power supply cables.
Capacity
Modules
Inverters
2.04 kWp
12 x SF170-S
1 x Turbo 1P Mini
2.38 kWp
14 x SF170-S
1 x Turbo 1P
2.97 kWp
18 x SF165-S
1 x Turbo 1P
3.06 kWp
18 x SF170-S
1 x Turbo 1P
3.06 kWp
18 x SF170-S
1 x Turbo 3P1
3.40 kWp
20 x SF170-S
1 x Turbo 1P
3.57 kWp
21 x SF170-S
1 x Turbo 1P
3.96 kWp
24 x SF165-S
1 x Turbo 1P
4.08 kWp
24 x SF170-S
1 x Turbo 1P
4.08 kWp
24 x SF170-S
1 x Turbo 3P1
4.76 kWp
28 x SF170-S
1 x Turbo 1P
5.10 kWp
30 x SF170-S
1 x Turbo 3P2
5.95 kWp
35 x SF170-S
1 x Turbo 3P2
7.14 kWp
42 x SF170-S
1 x Turbo 3P2
8.16 kWp
48 x SF170-S
2 x Turbo 1P
Inverter
Figure 2
Grid connection
1ph
1ph
1ph
1ph
3ph
1ph
1ph
1ph
1ph
3ph
1ph
3ph
3ph
3ph
1ph

4.3 Markings

4.3.1

Symbols

Symbol
Description
General danger warning
Danger from electricity
Read manual before using the product.
4.3.2

Keywords

Keywords used in conjunction with the symbols described above:
Keyword
Description
Danger
Immediate danger of death or serious bodily injury
Warning
Possible danger of death or serious bodily injury
Caution
Possible danger of light or medium bodily injury
Attention
Possible damage to property
Advice
Tips on operation or usage of the manual
4.3.3

Markings used in the text

Markings
Description
Condition for action
Single step
1., 2., 3., ...
Several steps in series
cursive
light emphasis
bold
strong emphasis
Designation of product elements such as buttons.,
Courier
displays, operating state
3
Plugs &
Modules
Y- cables
sockets
in series
3 (+) & 3 (-)
3 + 3
1 (+) & 1 (-)
3 + 3
2 (+) & 2 (-)
3 + 3
2 (+) & 2 (-)
3 + 3
2 (+) & 2 (-)
3 + 3
3 (+) & 3 (-)
3 + 3
2 (+) & 2 (-)
3 + 3
3 (+) & 3 (-)
3 + 3
3 (+) & 3 (-)
3 + 3
3 (+) & 3 (-)
3 + 3
3 (+) & 3 (-)
3 + 3
4 (+) & 4 (-)
6 + 6
4 (+) & 4 (-)
6 + 6
5 (+) & 5 (-)
6 + 6
6 (+) & 6 (-)
6 + 6
Location
Manual
Manual / device
Device
3
7
6
6
6
5
7
6
6
6
7
6
7
7
6