10.5 Plugs, sockets, DC cable and Y-cable
10.5.1
Product information for plug and socket
Manufacturer: Hosiden
Product: HSC2013 und HSC2014
Technical Data
Rated current
30A DC / 6.0mm², 30A DC / 4.0mm²,
20A DC / 4.0mm²,
25A DC / 2.5mm², 15A DC / 2.5mm²
Rated voltage
1000 V (IEC)
Test voltage
6 KV for 1 minute, 10 kV impulse (1.2/50μS) (IEC)
Typical contact resistance
max. 1m Ω
Contact material
Copper alloy
Contact system
Machined/Cold Formed or Stamped & Formed
with RADSOK® insert
Insulation material
Polycarbonate
Locking mechanism
Locking-Typ
Cable strain relief
Compression gland with ratcheting gland nut
Degree of protection
IP67 (when paired)
Protection class
II (IEC61140)
Degree of pollution
3 (IEC60664)
Overvoltage category
III (IEC60664)
Flame class
UL94-VO
Ambient temperature
-40 °C to 85 °C
range
10.5.2
Product information for DC cable
/ minimum requirements
(optionally available)
Manufacturer: HIS
Product: HIKRA® Plus or PlusXL
This cable is available from Solar Frontier.
Alternative cables used must at least be equivalent or fulfil the following technical
data and structural requirements.
Technical Data
Approvals
DKE (PV1-F), TÜV 2 PfG, 1169/08.07 (R 60089447)
Working temperature
-40 °C to +90 °C
Minimum bending radius
10 x cable dia
flexible
Minimum bending radius
5 x cable diameter
fixed
Rated voltage [U0/U]
AC 600 / 1.000 V | DC 900 / 1.500 V
Test voltage
AC 6.500 V
Rated voltage
Maximum permissible voltage up to 1.8 kV DC
(conductor/conductor, system not grounded,
circuit not under load)
General Construction
Number x section in mm²
1 x 4.0
Conductor construction n
56 x 0.31
x max-ø (mm)
External diameter approx.
5.7
(± 0.3 mm)
Weight ca. kg/km
38.4
Structure
Tin-plated copper strand, fine wire as per IEC 60228 class 5
Polyolefin
Double isolated
Insulation/chemically cross-linked special compound
1 x 6.0
80 x 0.31
6.4
57.6
22
10.5.3
Product information Y-cable
Manufacturer: HIS
Product: HISkon Splitter
Technical Data
Max. current capacity acc. IEC 60364-5-52 at 90°C,
single layed, free in air*; without PV-connectors.
* Reduction factor in case of cable accumulation IEC 60364-5-52, Table A.52-17
Main-cable
Trunk-cable
Nominal voltage
Contact resistance at welding point:
Overvoltage Category
Overview PV-connector Hosiden HSC 2013/2014
IP-class (mated)
Max. current capacity
Upper limited temperature
Contact Resistance
11. Exclusion of Liability
This manual is the proprietary information of Solar Frontier Europe GmbH (SF).
Solar Frontier´s limited warranty will be voided if the instructions herein are not
strictly observed. Solar Frontier will not assume any liability for personal injuries
or damage to property arising from improper use, wrong assembly, operation
or maintenance of PowerSets. Solar Frontier reserves the right to make amend-
ments to the contents of this document without prior notice. This version of the
installation and operation manual is valid from march 2016.
The information provided with this installation and operation manual represent
the latest information of the manufacturer of the single components at the
time of printing. Subject to changes and modifications.
12. Contact
In case of complaints or faults, please contact the dealer from whom you pur-
chased the product. They will help you with any issues you may have.
The PowerSet service provided by Solar Frontier:
Toll-free phone
number:
00800 333 111 333
E-mail:
powersets.aftersalesservice@solar-frontier.eu
Internet:
www.solar-frontier.eu
49.7 A
49.7 A
1000V DC
< 0.1mΩ
III
IIP67
30 A (6.0 mm²)
90°C
1.0mΩ