Download Inhoudsopgave Inhoud Print deze pagina

Dometic COOLMATIC HDC155 Gebruikershandleiding En Montagehandleiding pagina 20

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Installing and connecting the refrigerator
The refrigerator can be operated with a 12 V or 24 V DC voltage supply.
For safety reasons, the refrigerator is equipped with an electronic system to prevent
the polarity being reversed. This protects the refrigerator against reversed polarity
when connecting to a battery and against short circuiting.
To protect the battery, the refrigerator switches off automatically if the voltage is
insufficient (see table below).
Cut-off voltage
Cut-in voltage
➤ Determine the required cross section of the cable in relation to the cable length
according to fig. d, page 10.
Key for fig. d, page 10
Coordinate axis
l
A
NOTICE!
Make sure the polarity is correct.
➤ Before starting up the device for the first time, check whether the operating
voltage and the battery voltage match (see type plate).
➤ Connect the refrigerator
– as directly as possible to the poles of the battery or
– to a plug socket which is fuse protected with at least 15 A (at 12 V) or 7.5 A
(at 24 V).
20
12 V
10.4 V
11.7 V
Meaning
Cable length
Cable cross section
HDC155
24 V
22.8 V
24.2 V
Unit
m
mm²
EN

Advertenties

Inhoudsopgave
loading

Inhoudsopgave